- Main products: Series resonance test device, Transformer tester, Circuit breaker, switch tester, High Voltage Insulation Equipm, Relay Protection Products, Cable and cable fault tester, Arrester and Insulator Test In, SF6 Test Instrument, Oil Testing Instrument, DC System and Battery Test Ins, Ground/Insulation Resistance T, Power Energy Analyzer, Power Energy Analyzer
-
wangchengfeng
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

Functional characteristics of CVT AC resonance test system
2021-04-22 10:41:21
Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer.
1、Due to full compensation of resonant reactive power the power of power supply and equipment is less than 1/10 of the required capacity of the subject (1/Q>10). Small size and light weight with the same capacity large output capacity of the device and small power capacity required cheap convenient and safe to use;
2、Series resonance is actually a current filtering circuit so that the current passing through the subject is basically the fundamental current and the waveform distortion rate (THD) of the output voltage is very small which is superior to all existing ac voltage withstand equipment.
3、The short circuit current of the sample after flashover or breakdown is only less than 1/10 (1/Q) of the test current before short circuit which can effectively prevent the expansion of damage to the fault point after breakdown;
4、After flashover the arc will be automatically extinguished immediately. The long (number of seconds) process of restoring resonant state voltage after arc quenching is a steady-state establishment process and there is no danger of voltage overshoot and no danger of restoring overvoltage in microsecond millisecond transient process.
-
Rexroth proportional pressure relief valve 0811402036 DBETX-10/50G24-8NZ4M
-
Rexroth DIRECTIONAL SPOOL VALVE R900561274 WE6D6X/EG24N9K4
-
Rexroth DIRECTIONAL SPOOL VALVE R900568233 4WE 6 W62/EG24N9K4
-
Rexroth PRESSURE REDUCING VALVE DRE6X-12/175MG24-8NZ4M 0811402055
-
Festo flow sensor SFAB-200U-WQ8-2SA-M12
-
ITD21H01 02048 H NIS21SG8 E 14IP65 019 Sensors & switches from BAUMER ELECTRIC
-
Bender IRDH275B-427
-
ABB NRED-61-E
-
ELMO CEL-3/100-C6
-
Matrox G45X2DUAL-BF
-
Siemens 6SE7036-0EF85-0EA0
-
Siemens 6RY1233-0DA04
Popular Searches
- power transformer
- distribution service
- current transformer
- high frequency transformer
- electrical transformer
- energy saver device
- step up converter
- ac drive converter
- frequency drive converter
- lightning conductor
- copper lightning rod
- electronic transformer
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer